Opening & Daily Closing Procedures C717/C709
Heat Treatment & Helpful Tips
Opening Procedures
- Prepare a small amount approved sanitizer. Container or spray bottle
- Sanitize door Spout(s) and bottom draw valves for 1 minute. Install red design rings
- When ready to resume normal operation, touch the auto snowflake symbol. When the unit cycles off the product in the freezing cylinder will be ready to serve.
- Place all cleaned and sanitized parts back in place. *Note the mix feed tube hole down
- Use a clean, sanitized towel, wipe down the freezer door front panel and area around the bottom of the freezer door, and any other areas that demonstrate a buildup of either moisture or soft serve mix.
Flavor Burst 8 Flavor Injection Option
- Install the clean and sanitized Flavor Burst Assembly to the Taylor freezer
- Check the operation
- Hold a cup under the Flavor Burst spout. Push the sanitizer button on the Keypad or Color Touch Panel to sanitize the assembly.
Daily Closing Procedures
- Remove drip pan(s), front drip tray, splash shield and air orifice(s), red design caps and place on a clean dry surface to air dry overnight
- Remove: Mix feed tube(s) – Air orifice(s) – Agitator(s) – Hopper cover(s) clean and sanitize, put back in place. Note: Mix Feed tube side hole in the up position
- Fill Mix level between the low high marks on the agitator
- Be sure the agitator(s) are installed, and the power switch is on, and are in either the Auto/Snowflake or Standby/Rain Drop mode or the unit will not have a successful heat treat cycle.
- Sanitize door Spout(s) and bottom draw valves for 1 minute.
- Auto Heat Cycle Good to go…. Manual Heat Cycle touch the Sun/Heat treatment symbol
- Use a clean, sanitized towel, wipe down the freezer door front panel and area around the bottom of the freezer door, and any other areas that demonstrate a buildup of either moisture or soft serve mix.
Flavor Burst 8 Flavor Injection Option
- Hold a cup under the Flavor Burst spout. Push the sanitizer button on the Keypad or Color Touch Panel to sanitize the assembly.
- Remove the Flavor Burst assembly, clean and sanitize let air dry
- Cap the injector syrup tube